A three-phase generator (400 V) is needed when you power three-phase loads such as a borehole pump, a pressure-booster set, a compressor or workshop machines; for ordinary 230 V sockets a single-phase generator is enough. In our catalogue all WEIMA generators are single-phase (230 V sockets, listed as 220 V on the product pages), and we have no three-phase models in the range. If you need 400 V, call us and we will help you find a solution.
When you need a three-phase generator
The rating plate on the equipment tells you how many phases you need. A marking such as "3~ 400 V" means a three-phase load. A marking of "230 V" means single-phase.
| What you power | Supply | Which generator |
|---|---|---|
| lighting, fridge, router, hand power tools, a 230 V pump | 230 V, one phase | single-phase |
| three-phase pressure-booster set or borehole pump, lathe, milling machine, circular saw, 400 V compressor | 400 V, three phases | three-phase |
| a house with three-phase wiring where in an outage you power only selected circuits (lights, fridge, boiler) | 230 V on selected circuits | usually a single-phase unit is enough, connected to those circuits by an electrician |
| a whole house with three-phase loads | 400 V | three-phase with a changeover system, sized with an electrician |
A three-phase motor needs all three phases. You cannot start it from a single-phase generator, and running on two phases can damage it.
A 10 kW generator: what it means
Generators of around 10 kW are usually three-phase. Power is given in kW (real power) or kVA (apparent power); the conversion is kW = kVA × cos φ, often 0.8 on rating plates. So 10 kVA is about 8 kW. The largest generator in our range, the WEIMA WM8500E, has a rated power of 7.5 kW (8.5 kW maximum) and is single-phase. We do not have a 10 kW generator.
Why not power a house "on one phase" from a three-phase generator
A three-phase generator has three windings, each serving its own phase. If you connect the whole house to one phase, a single winding carries the entire load while the other two are almost idle. This is called phase imbalance: the loaded phase overheats and its voltage sags, while the others can run at a higher voltage. The generator manufacturer states in the manual how much power you may draw from one phase; it is usually clearly less than the power of the whole unit. Without knowing your load, it is easy to exceed. Do not bridge the phases together "for convenience" either: an electrician chooses the wiring.
How to connect a generator to the installation safely
- A mains/generator changeover switch or an automatic transfer system (SZR). The generator is connected to the house wiring through a switch that stops generator power from flowing out to the grid. An SZR automatically watches the mains voltage and switches the supply to the generator. A qualified electrician installs the switch.
- Do not plug a generator into a wall socket with a double-ended cable. Voltage can flow out to the grid, which is dangerous, including for people repairing it.
- Check with the electrician how the neutral conductor is disconnected, plus earthing and protection.
- Size the power with spare capacity. Motors (pumps, compressors) draw several times more at start-up than while running.
We cover general power sizing in the guide how to choose a generator and prices in how much a home generator costs.
What we have in stock
Single-phase WEIMA generators, 230 V; prices as of 20.11.2026:
| Model | Rated / max power | Price |
|---|---|---|
| WM2500B | 2.0 / 2.5 kW | 1459 zł |
| WM3200B | 2.8 / 3.2 kW | 1559 zł |
| WM5500BE with remote start | 5.0 / 5.5 kW | 2999 zł |
| WM8500E with remote start | 7.5 / 8.5 kW | 3699 zł |
If you only need water, not electricity, consider a petrol-engine water pump: it has its own engine and works without a generator. In-stock pumps start from 689 zł; see the guide how to choose a water pump.
Frequently asked questions
Can a single-phase generator power a three-phase booster set or pump?
Not directly. A three-phase motor needs three phases. Frequency converters and phase converters exist, but leave their selection to an electrician and the pump maker.
Do you have 400 V three-phase generators?
No. All our WEIMA generators are single-phase with 230 V sockets. Call us if you need 400 V and we will advise how to approach it.
Can I plug a generator into a wall socket at home?
Do not do that. A generator is connected through a mains/generator changeover switch installed by an electrician, so that power does not flow out to the grid.
How much power do I need for a pump?
Check the motor power and starting current on the rating plate, and choose a generator with spare capacity, because a motor draws several times more at start-up than while running.
Not sure whether you need a three-phase generator? Call +48 577 058 408, we advise by phone in Polish, Ukrainian and Russian. Single-phase models are in the generators category.